> product_In_Use: SCL//MRS-Pbsfty/RSD/comkbo CC
> Radio_In_Use: Pro-106, Radio Shack
> Cable In Use: 20-047
> Dealer: C. A. T.
> Comments: When downloading from scanner, numbered banks do not enter into
> correct Scancat banks. Radio Shack advises there is a known issue with this
> scanner. Radio Shack indicates update 1.4.6 addresses this problem. How do I
> get it? Or must I purchase the update to solve your programming problem?
---------------------------------------------------------------------------
HI
This can occur on conventional systems if there are several in sequential banks..... IE: Bank/System 1-2-3 etc. The best way to prevent this is to place conventional systems into alternating banks. It is a quirk with the way the system pointers are assigned in the radio. And when we read a conventional system there doesn't seem to be any way to tell where one conventional system begins and another conventional system ends
So .... we find this works ----
Put a conventional system in System 1
Put a trunking system into System 2
Put a conventional system in System 3
Put a trunking system into System 4
Put a conventional system in System 5
Put a trunking system into System 6
Etc
Then they will line up like they are displayed in the radio.
I wish there was a better answer. Even though we are "connected" with Radio Shack, We get practically No technical help from the manufacturer(GRE) - (basically nill), and they have never been able to give us a better solution.
Best Regards
Jim